技术属性

一般信息
Brand ÖLFLEX®
Product type Power and control cable
Copper index 48.000  kg/km
Copper index (lb) 322.500  lb
Weight 117 kg/km
电气特性
Nominal voltage U0/U: 300/500 V AC rms according to IEC
Max. conductor resistance at 20°C 20  Ω/km
Inductance (800 Hz), approx. 0.739
Test voltage 3.5  kV
Current rating according to VDE 0298-4
Conductor/conductor operating capacitance (800Hz), approx. 60
产品设计
Conductor design IEC 60228 class 5: fine-wire
Nominal outer diameter 8.6  mm
Conductor material Tin-plated copper
Nominal conductor cross-section (metric) 1  mm²
Cable dimension 5G1
Shielded

Core identification Colours
Shape of cable Round
Outer sheath colour yellow
Stranding type Layered stranding
Cable sheath RAL colour RAL 1016
Conductor colour code VDE 0293-308
Number of cores 5
Core insulation basic material Thermoplastic elastomers
Basic material of outer sheath Polyurethane
Including protective earth

Core insulation basic material, short form TPE
Basic material of outer sheath, short form PUR
产品特点
Flame-retardant

PWIS-free according to VDMA 24364-B2-L
Halogen-free according to VDE 0472-815
Permanent underwater use up to 10
Can be used permanently underwater according to EN 50525-2-21
Storage temperature min. -25
Chemical resistant

UV-resistant

hydrolysis resistant

Minimum bending radius in mm, fixed installation 34.4  mm
PWIS-free

Application area Flexible, Fixed installation
max. conductor temperature, occasionally moved -40 °C to 90 °C max. conductor temperature:
Oil-resistant

MUD resistance according to IEC 61892-4
Max. storage temperature 55
Minimum bending radius in mm, occasionally flexing 86.0  mm
weather resistant

Minimum bending radius, stationary 4 x outer diameter
Water resistant

Minimum bending radius, occasionally flexing 10 x outer diameter
Temperature, fixed installation -50 °C to 90 °C max. conductor temperature:
Flame retardance according to IEC 60332-1-2
Permanently immersible in water

Oil resistance according to EN 50363-10-2
UV-resistant according to EN ISO 4892-2, method A (colour change permitted), EN 50618, EN 50620
Halogenfree

认证和标准
cUR recognized

CSA certified

HAR-certified

Ecolab certified

cUL listed

Flame retardance tested according to UN/ECE-R118

UL listed

VDE registration number 6583
CE marked

UL recognized

VDE certified

EAC certification number ЕАЭС N RU Д-DE.АЮ64.В.00130/20
EAC-certified

文档
产品系列列表
All articles from ÖLFLEX® 540 P
Article number Number of cores Including protective conductor Conductor cross-section (mm2) Nominal voltage Imp outer dia cable sheath nom Nominal outer diameter Copper index calc export Weight
0012452 2 No 0.75 U0/U: 300/500 V AC rms according to IEC 6.2 55 kg/km
0012453 3 Yes 0.75 U0/U: 300/500 V AC rms according to IEC 6.7 56 kg/km
0012456 7 Yes 0.75 U0/U: 300/500 V AC rms according to IEC 9.9 126 kg/km
0012457 2 No 1 U0/U: 300/500 V AC rms according to IEC 6.7 53 kg/km
0012458 3 Yes 1 U0/U: 300/500 V AC rms according to IEC 7.1 72 kg/km
0012461 7 Yes 1 U0/U: 300/500 V AC rms according to IEC 10.4 147 kg/km
0012462 2 No 1.5 U0/U: 450/750 V AC rms according to IEC 8.3 82 kg/km
0012463 3 Yes 1.5 U0/U: 450/750 V AC rms according to IEC 8.8 111 kg/km
0012466 7 Yes 1.5 U0/U: 450/750 V AC rms according to IEC 13.4 307 kg/km
0012467 2 No 2.5 U0/U: 450/750 V AC rms according to IEC 9.7 159 kg/km
0012468 3 Yes 2.5 U0/U: 450/750 V AC rms according to IEC 10.3 161 kg/km
0012471 7 Yes 2.5 U0/U: 450/750 V AC rms according to IEC 15.8 367 kg/km
0012474 3 Yes 4 U0/U: 450/750 V AC rms according to IEC 12.3 219 kg/km
00124543 4 Yes 0.75 U0/U: 300/500 V AC rms according to IEC 7.3 68 kg/km
00124553 5 Yes 0.75 U0/U: 300/500 V AC rms according to IEC 8.2 98 kg/km
00124593 4 Yes 1 U0/U: 300/500 V AC rms according to IEC 7.7 96 kg/km
00124603 5 Yes 1 U0/U: 300/500 V AC rms according to IEC 8.6 117 kg/km
00124643 4 Yes 1.5 U0/U: 450/750 V AC rms according to IEC 9.8 131 kg/km
00124653 5 Yes 1.5 U0/U: 450/750 V AC rms according to IEC 10.7 164 kg/km
00124693 4 Yes 2.5 U0/U: 450/750 V AC rms according to IEC 11.4 220 kg/km
00124703 5 Yes 2.5 U0/U: 450/750 V AC rms according to IEC 12.7 245 kg/km
00124753 4 Yes 4 U0/U: 450/750 V AC rms according to IEC 13.6 284 kg/km
00124763 5 Yes 4 U0/U: 450/750 V AC rms according to IEC 15.2 355 kg/km
00124783 4 Yes 6 U0/U: 450/750 V AC rms according to IEC 15.4 440 kg/km
00124793 5 Yes 6 U0/U: 450/750 V AC rms according to IEC 17.1 530 kg/km
00124813 4 Yes 10 U0/U: 450/750 V AC rms according to IEC 20.1 615 kg/km
00124823 5 Yes 10 U0/U: 450/750 V AC rms according to IEC 22.3 735 kg/km