Technical Attributes

General Information
Brand ÖLFLEX®
Product type Motor connection cable
Copper index 214.272  kg/km
Copper index (lb) 1440.000  lb
Weight 384 kg/km
Electrical Characteristics
Nominal voltage U0/U: 0,6/1 kV AC rms according to IEC
Max. conductor resistance at 20°C 5.09  Ω/km
Test voltage 6  kV
Rated voltage 600 V AC rms according to UL TC, 2000 V AC rms according to UL TC, 1000 V AC rms according to UL flexible motor supply, 600 V AC rms according to c(UL) CIC/TC, 1000 V AC rms according to cRU AWM, 1000 V AC rms according to UL WTTC
Power cores nominal voltage U0/U: 0,6/1 kV AC rms according to IEC
Product Design
Conductor design IEC 60228 class 5: fine-wire
Nominal outer diameter 16.7  mm
Conductor material Tin-plated copper
Nominal conductor cross-section (metric) 4  mm²
Conductor count/size 4G4
Shielded

Core identification Numbers
Shape of cable Round
Outer sheath colour black
Stranding type Layered stranding
Leading conductor cross-section mm²
Cable sheath RAL colour RAL 9005
Conductor colour code EN 50334, VDE 0293-1
Type of overall screen Tin-plated copper braiding, Aluminium-laminated plastic foil
Cable element 1 Power core: 4G4
Number of cores 4
Nominal conductor cross-section (AWG) 12 AWG
Core insulation basic material Cross-linked polyethylene
Basic material of outer sheath Thermoplastic elastomers
Including protective earth

Core insulation basic material, short form XLPE
Basic material of outer sheath, short form TPE
Product Characteristics
Flame-retardant

Low capacitance

UV-resistant

Minimum bending radius in mm, fixed installation 125.3  mm
Application area Flexible, Fixed installation
max. conductor temperature, occasionally moved -25 °C to 105 °C max. conductor temperature: according to UL AWM, -25 °C to 105 °C max. conductor temperature: according to CSA AWM
Oil-resistant

Minimum bending radius in mm, occasionally flexing 250.5  mm
Minimum bending radius, stationary 7.5 x outer diameter
Minimum bending radius, occasionally flexing 15 x outer diameter
Temperature, fixed installation -40 °C to 105 °C max. conductor temperature: according to UL AWM, -40 °C to 105 °C max. conductor temperature: according to CSA AWM, -25 °C to 90 °C max. conductor temperature: according to UL/CSA TC
Flame retardance according to UL Vertical-Tray Flame Test, CSA FT4
Oil resistance according to UL OILRES I, UL OILRES II
UV-resistant according to UL sunlight resistant, EN 50525-1 (cables with a black sheath are suitable for permanent outdoor use)
Halogenfree

Certifications and Standards
cUR recognized

CSA certified

UL certification UL TC-ER according to UL 1277 (e-file number: E171371), UL WTTC according to UL 2277 (e-file number: E323700), UL Flexible Motor Supply Cable according to UL 2277 (e-file number: E362141)
cUL listed

Flame retardance tested according to UN/ECE-R118

UL listed

cUR certification AWM I A according to CSA C22.2 No. 210 (e-file number: E100338), AWM I B according to CSA C22.2 No. 210 (e-file number: E100338), AWM II A according to CSA C22.2 No. 210 (e-file number: E100338), AWM II B according to CSA C22.2 No. 210 (e-file number: E100338)
CE marked

cUL certification cUL CIC/TC 600V according to CSA C22.2 No. 239 (e-file number: E171371)
UL recognized

EAC certification number ЕАЭС RU С-DE.АЮ64.В.00091/19
EAC-certified

Documentation
Notes
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
Product Family List
All articles from ÖLFLEX® VFD 2XL
Article number Conductor count/size Imp outer dia cable sheath nom Nominal conductor cross-section (AWG) Nominal outer diameter Copper index calc export Weight Conductor cross-section (mm2) Number of cores Including protective conductor Sap net weight Copper index (lb)
700700 4G1.5 16 AWG 12.9 238 kg/km 1.5 4 Yes 700.000
700701 4G2,5 14 AWG 14.8 292 kg/km 2.5 4 Yes 1000.000
700702 4G4 12 AWG 16.7 384 kg/km 4 4 Yes 1440.000
700703 4G6 10 AWG 18 476 kg/km 6 4 Yes 1990.000
700704 4G10 8 AWG 22.5 856 kg/km 10 4 Yes 2980.000
700705 4G16 6 AWG 25.9 1317 kg/km 16 4 Yes 5180.000
700706 4G4AWG 4 AWG 29.4 1570 kg/km 21 4 Yes 6122.000
700707 4G2AWG 2 AWG 33.8 2172 kg/km 33 4 Yes 9734.000