Technical Attributes

General Information
Brand UNITRONIC®
Product type Ethernet cable
valid fieldbus or Ethernet system Ethernet, ETHERNET/IP, EtherCAT
Copper index 27.000  kg/km
Copper index (lb) 181.400  lb
Weight 60 kg/km
Electrical Characteristics
Maximum operating voltage (not for power transmission) 100
Nominal surge impedance 100
Segregation class according to EN 50174-2 D
Supports Power over Ethernet IEEE 802.3af (PoE), IEEE 802.3at (PoE+), IEEE 802.3bt (4PPoE)
Loop resistance at 20°C 150
Possible data transmission rates 10000
Signal propagation speed (nom.) 0.79
Test voltage core/core 0.7
Product Design
Nominal core diameter 1.37
Conductor design solid conductor
Nominal outer diameter 7.5  mm
Conductor material Bare copper
Nominal conductor cross-section (metric) 0.25  mm²
Conductor count/size 4x2x23/1AWG
Shielded

Core identification Colours
Shape of cable Round
Number of pairs 4
Outer sheath colour yellow
Stranding type Twisted-pair
Pair screening type Aluminium-laminated plastic foil
Leading conductor cross-section AWG
Abbreviation shielding S/FTP
With rodent protection

Type of overall screen Copper braiding
Number of cores 8
Nominal conductor cross-section (AWG) 23 AWG
Core insulation basic material Polyethylene foam
Basic material of outer sheath Halogen-free compound
Including protective earth

Core insulation basic material, short form Foam-Skin PE
With armouring

Number of wires 1
Basic material of outer sheath, short form LSZH
Product Characteristics
Flame-retardant

PWIS-free according to VDMA 24364-B2-L
Halogen-free according to IEC 60754-1, IEC 60754-2
Corrosiveness of combustion gases according to EN 50267-2-2, IEC 60754-2
Fast Connect (FC) cable

Installation temperature min. 0
UV-resistant

Minimum bending radius in mm, fixed installation 30.0  mm
PWIS-free

Application area Fixed installation
Oil-resistant

Ethernet cable category Cat.7
Minimum bending radius in mm, occasionally flexing 60.0  mm
Max. assembly temperature 50
Minimum bending radius, stationary 4 x outer diameter
Minimum bending radius, occasionally flexing 8 x outer diameter
Temperature, fixed installation -20 °C to 60 °C max. conductor temperature:
Flame retardance according to IEC 60332-3-24, IEC 60332-1-2
Installation type Cable tray
Windable

Halogenfree

Certifications and Standards
CE marked

CPR fire class Eca
VDE certified

EAC certification number ЕАЭС N RU Д-DE.АЮ64.В.00130/20
EAC-certified

Documentation
Notes
  • Photographs and graphics are not to scale and do not represent detailed images of the respective products.
  • Unless specified otherwise, the product values shown are rated values at room temperature. You can receive further values, such as tolerances, upon request if they are available and have been released for publication.
Product Family List
All articles from ETHERLINE® LAN 1000 Cat.7A
Article number Conductor count/size Imp outer dia cable sheath nom Nominal outer diameter Shape of cable Flame retardance according to Copper index calc export Weight
2170614 4x2x23/1AWG 7.5 Round IEC 60332-3-24, IEC 60332-1-2 60 kg/km
2170971 4x2x23/1AWG 7.4 Round IEC 60332-3-24 56 kg/km
2170972 2x(4x2x23/1AWG) 7.4 Separable twin IEC 60332-3-24 113 kg/km
2170980 4x2x23/1AWG 7.2 Round IEC 60332-1-2 50 kg/km
2170981 2x(4x2x23/1AWG) 7.2 Separable twin IEC 60332-1-2 101 kg/km